能自动感测送风温度,自动调整送风方向。夏季送风温度低于17°C时,风口气流呈水平贴附扩散气流。冬季送风温度高于28°C时,风口气流呈垂直下送状态,能够获得更远的送风距离。感温执行机构无需电源,具有节能、环保、免维护、性能稳定,智能化等优点。
说明
具体规格有ΦI50、Φ200、Φ250、Φ300、Φ350、Φ400、Φ450。可选配件为蝶阀。定制形式:手动型、感温型。
SH一YS温控散流器尺寸图

SH一YS温控散流器型号表示方法

SH一YS温控散流器尺寸对照表
| 型号规格 | 颈尺寸(mm) | 面尺寸(mm) | 开洞尺寸(mm) | T(mm) | w(mm) | H(mm) |
| WATCD-F-150 | 150 | 338 | 285 | 15 | 30 | 125 |
| WATCD-F-200 | 200 | 438 | 385 | 15 | 30 | 135 |
| WATCD-F-250 | 250 | 502 | 450 | 20 | 30 | 145 |
| WATCD-F-300 | 300 | 608 | 520 | 25 | 45 | 155 |
| WATCD-F-350 | 350 | 708 | 620 | 25 | 45 | 165 |
| WATCD-F-400 | 400 | 808 | 720 | 25 | 45 | 175 |
| WATCD-F-450 | 450 | 908 | 820 | 25 | 45 | 185 |
SH一YS温控散流器性能表
| 型号规格 | 颈部风速m/s | 2 | 2.5 | 3 | 3.5 | 4 | 4.5 | 5 | 6 | 6.5 | |
| WATCD-F -150 | 风量m3/h | 127 | 159 | 191 | 223 | 254 | 286 | 318 | 382 | 413 | |
| 静压损失pa | H | 2 | 3 | 5 | 6 | 8 | 10 | 13 | 18 | 21 | |
| V | 5 | 8 | 11 | 15 | 20 | 25 | 31 | 45 | 53 | ||
| 扩散半径m | H | 0.5 | 0.6 | 0.8 | 0.9 | 1 | 1.2 | 1.3 | 1.6 | 1.8 | |
| 到达距离m | V | 1.1 | 1.4 | 1.6 | 1.9 | 2.2 | 2.5 | 2.7 | 3.3 | 3.6 | |
| 发生噪音dB(A) | H | - | - | - | 26 | 28 | 31 | 33 | 36 | 40 | |
| V | - | - | 26 | 28 | 30 | 32 | 34 | 37 | 42 | ||
| WATCD-F -200 | 风量m3/h | 226 | 283 | 339 | 396 | 452 | 509 | 565 | 678 | 735 | |
| 静压损失pa | H | 2 | 3 | 5 | 6 | 8 | 10 | 13 | 18 | 21 | |
| V | 5 | 8 | 11 | 15 | 20 | 25 | 31 | 45 | 53 | ||
| 扩散半径m | H | 0.7 | 0.9 | 1.1 | 1.3 | 1.4 | 1.6 | 1.8 | 2.2 | 2.4 | |
| 到达距离m | V | 1.4 | 1.8 | 2.1 | 2.5 | 2.9 | 3.2 | 3.6 | 4.3 | 4.6 | |
| 发生噪音dB(A) | H | - | 26 | 28 | 30 | 32 | 34 | 36 | 38 | 42 | |
| V | - | 28 | 31 | 32 | 35 | 36 | 38 | 40 | 44 | ||
| WATCD-F -250 | 风量m3/h | 286 | 358 | 429 | 501 | 572 | 644 | 715 | 858 | 930 | |
| 静压损失pa | H | 2 | 3 | 5 | 6 | 8 | 10 | 13 | 18 | 21 | |
| V | 5 | 8 | 11 | 15 | 20 | 25 | 31 | 45 | 53 | ||
| 扩散半径m | H | 0.9 | 1.1 | 1.4 | 1.6 | 1.8 | 2 | 2.3 | 2.7 | 2.9 | |
| 到达距离m | V | 1.8 | 2.2 | 2.7 | 3.1 | 3.5 | 4 | 4.5 | 5.3 | 5.8 | |
| 发生噪音dB(A) | H | 26 | 28 | 30 | 32 | 34 | 36 | 38 | 41 | 43 | |
| V | 28 | 30 | 32 | 34 | 37 | 39 | 41 | 42 | 45 | ||
| WATCD-F -300 | 风量m3/h | 509 | 636 | 763 | 890 | 1017 | 1145 | 1272 | 1526 | 1653 | |
| 静压损失pa | H | 2 | 3 | 5 | 6 | 8 | 10 | 13 | 18 | 21 | |
| V | 5 | 8 | 11 | 15 | 20 | 25 | 31 | 45 | 53 | ||
| 扩散半径m | H | 1 | 1.3 | 1.6 | 1.8 | 2.1 | 2.4 | 2.6 | 3.1 | 3.4 | |
| 到达距离m | V | 2.1 | 2.6 | 3.1 | 3.7 | 4.1 | 4.7 | 5.2 | 6.3 | 6.8 | |
| 发生噪音dB(A) | H | 28 | 30 | 32 | 35 | 36 | 37 | 39 | 42 | 44 | |
| V | 31 | 33 | 35 | 37 | 38 | 40 | 42 | 43 | 46 | ||
| WATCD-F -350 | 风量m3/h | 692 | 866 | 1039 | 1212 | 1384 | 1558 | 1731 | 2077 | 2250 | |
| 静压损失pa | H | 2 | 3 | 5 | 6 | 8 | 10 | 13 | 18 | 21 | |
| V | 5 | 8 | 11 | 15 | 20 | 25 | 31 | 45 | 53 | ||
| 扩散半径m | H | 1.2 | 1.5 | 1.8 | 2.1 | 2.4 | 2.7 | 3 | 3.6 | 3.9 | |
| 到达距离m | V | 2.5 | 3 | 3.6 | 4.2 | 4.8 | 5.4 | 6 | 7.2 | 7.5 | |
| 发生噪音dB(A) | H | 29 | 30 | 32 | 35 | 37 | 39 | 41 | 43 | 45 | |
| V | 31 | 32 | 35 | 37 | 39 | 41 | 43 | 45 | 47 | ||
| WATCD-F -400 | 风量m3/h | 904 | 1130 | 1357 | 1583 | 1808 | 2035 | 2261 | 2713 | 2939 | |
| 静压损失pa | H | 2 | 3 | 5 | 6 | 8 | 10 | 13 | 18 | 21 | |
| V | 5 | 8 | 11 | 15 | 20 | 25 | 31 | 45 | 53 | ||
| 扩散半径m | H | 1.3 | 1.7 | 2 | 2.3 | 2.7 | 3 | 3.3 | 4 | 4.3 | |
| 到达距离m | V | 3 | 3.8 | 4.5 | 5.3 | 6 | 6.8 | 7.5 | 9 | 9.8 | |
| 发生噪音dB(A) | H | 31 | 33 | 35 | 37 | 39 | 40 | 42 | 44 | 46 | |
| V | 33 | 36 | 38 | 40 | 42 | 42 | 44 | 46 | 48 | ||
| WATCD-F -450 | 风量m3/h | 1145 | 1431 | 1717 | 2003 | 2289 | 2575 | 2861 | 3434 | 3720 | |
| 静压损失pa | H | 2 | 3 | 5 | 6 | 8 | 10 | 13 | 18 | 21 | |
| V | 5 | 8 | 11 | 15 | 20 | 25 | 31 | 45 | 53 | ||
| 扩散半径m | H | 1.4 | 1.8 | 2.1 | 2.5 | 2.8 | 3.1 | 3.5 | 4.2 | 4.5 | |
| 到达距离m | V | 3.7 | 4.6 | 5.6 | 6.5 | 7.4 | 8.3 | 9.2 | 11.1 | 12 | |
| 发生噪音dB(A) | H | 31 | 33 | 35 | 37 | 39 | 41 | 43 | 45 | 47 | |
| V | 34 | 37 | 39 | 40 | 42 | 43 | 45 | 47 | 49 | ||
| 注:1、H表示水平贴附气流,V表示垂直下送气流,到达距离、扩散半径是指风口到0.5m/s处的距离。2、上表中数据是以等温气流为测试对象。3、非等温气流需根据送风温差,到达距离、扩散半径需要修正。 | |||||||||||