0512-63326698

Air Outlet Series >> Displacement Air Outlet Series

FK-WLXL Temperature Control Vortex Swirl Diffuser

Suitable for installation on ceilings of large spaces. It can automatically sense the supply air temperature and switch the airflow distribution mode automatically in winter and summer.

Product Description
Application and Characteristics
Suitable for installation on ceilings of large spaces. It can automatically sense the supply air temperature and switch the airflow distribution mode automatically in winter and summer.
In summer, the built-in blades open to form a vortex airflow for full-area air discharge.
In winter, the built-in blades close, and hot air is discharged only from the central cylinder to achieve a longer air supply distance, solving the problem that hot air is difficult to flow downward.
The temperature-sensing actuator requires no power supply, featuring energy saving, environmental friendliness, maintenance-free operation, stable performance and intelligent control.
Specification: Neck sizes Φ200, Φ250, Φ300, Φ350, Φ400, Φ450, Φ500.
Custom types: Manual type, electric type, temperature-sensing type.

FK-WLXL Temperature Control Vortex Swirl Diffuser Size Comparison Table
Model & Specification Neck Size (mm) Face Size (mm) Opening Size (mm) H(mm)
FKWLXL-8 Φ200 Φ243 Φ215 300
FKWLXL-10 Φ250 Φ293 Φ265 320
FKWLXL-12 Φ300 Φ342 Φ315 350
FKWLXL-14 Φ350 Φ393 Φ365 350
FKWLXL-16 Φ400 Φ450 Φ415 380
FKWLXL-18 Φ450 Φ510 Φ465 418
FKWLXL-20 Φ500 Φ560 Φ520 465
FKWLXL-22 Φ550 Φ602 Φ565 490


Performance Table of FK-WLXL Temperature Controlled Vortex Swirl Diffuser

Model & Specification Neck Air Velocity (m/s)
1.5 2 3 4 5 6
Static Pressure Loss (Pa) H 5 9 21 37 57 82
V 7 12 27 48 75 108
FKWLXL-8 Φ200 Neck Air Velocity (m/s)
162 217 325 434 542 651
Cold throw distance (m) H 2.6 3.4 5.1 6.7 8.3 9.8
Hot drop distance (m) V 4 5.3 79 10.5 13.1 15.5
Noise Level dB (A) H 32 37 41
V 31 36 41 46
FKWLXL-10 Φ250 Neck Air Velocity (m/s)
265 350 530 706 880 1030
Cold throw distance (m) H 2.8 3.7 5.5 7.3 9.1 10.8
Hot drop distance (m) V 4.9 6.5 9.6 12.8 15.8 18.6
Noise Level dB (A) H 30 34 39 43
V 31 35 38 43 48
FKWLXL-12 Φ300 Neck Air Velocity (m/s)
376 500 752 1003 1255 1505
Cold throw distance (m) H 3.3 4.4 6.5 8.1 9.6 11.5
Hot drop distance (m) V 5.8 7.7 11.5 15.4 19.2 23
Noise Level dB (A) H 31 35 40 44
V 32 36 39 44 49
FKWLXL-14 Φ350 Neck Air Velocity (m/s)
507 676 1015 1352 1690 2030
Cold throw distance (m) H 3.8 5 7.5 10 12.6 15
Hot drop distance (m) V 6.6 8.8 13.5 17.5 21.8 26.1
Noise Level dB (A) H
30 33 37 42 46
V 34 38 41 46 51
FKWLXL-16 Φ400 Neck Air Velocity (m/s)
665 886 1329 1772 2216 2660
Cold throw distance (m) H 4.3 5.7 8.6 11.3 14.1 16.9
Hot drop distance (m) V 7.5 10 15 20 25.1 30.1
Noise Level dB (A) H 32 35 39 43 47
V 36 40 43 47 52
FKWLXL-18 Φ450 Neck Air Velocity (m/s)
843 1124 1686 2248 2810 3372
Cold throw distance (m) H 4.8 6.4 96 12.8 16 19.2
Hot drop distance (m) V 8.4 11.2 16.8 22.4 28 33.6
Noise Level dB (A H 34 37 41 45 48
V 33 38 41 44 48 53
FKWLXL-20 Φ500 Neck Air Velocity (m/s)
1042 1390 2085 2780 3476 4170
Cold throw distance (m) H 5.3 7 10.5 14.1 17.6 21
Hot drop distance (m) V 9.3 12.4 18.6 24.8 30.8 36.9
Noise Level dB (A) H 32 36 39 44 47 50
V 37 40 43 46 50 88
FKWLXL-22 Φ550 Neck Air Velocity (m/s)
1164 1552 2328 3100 3880 4655
Cold throw distance (m) H 6.4 9.1 13.5 16.7 22.2 26.5
Hot drop distance (m) V 10.8 14.6 21.8 28.5 36 42
Noise Level dB (A) H 35 38 41 45 48 51
V 39 42 45 48 52 56

previous: SH-FS Thermostatic Square Diffuser

Next:SH-ZY Seat Air Outlet

Message